Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
2/2-Way Active Slip-In Cartridge Valve
Series TDW
8-94
TDW UK.indd 11.07.17
TDW025
TDW040
Function symbols
Characteristics
The series of active pilot operated 2/2-way cartridge
valves TDW enables to open and close the main poppet
solely by pilot pressure, independent of pressure build-up
in the main ports A and B.
The main poppet is designed hollow and mostly pressure
balanced. The operation is accomplished via minimal
control surfaces resulting in low pilot oil demand and fast
switching operations.
TDW is supplied as one unit to ensure easy installation
– sleeve and body are screwed together. Additionally,
the lower recess in the standardized mounting cavity is
no longer required, providing the possibility to minimize
pressure losses in the manifold block.
Features
Active pilot operated 2/2-way cartridge valves
Cavity and mounting pattern according to ISO 7368
Flow direction B to A and A to B
7 sizes NG25 up to NG100
Position monitoring optional
Stroke limiter optional
YXAB
TP
BA
Code 1
Pilot with DC valve,
normally open
BA
P
optional
position control
MY
1)
MA
1)
MB
1)
SP
2)
XX
1)
YXAB
P
BA
Code 2
Pilot with
cover plate
BA
P
optional
position control
MY
1)
MA
1)
MB
1)
SP
2)
XX
1)
YXAB
TP
BA
Code 9
Pilot with DC valve,
normally closed
BA
P
optional
position control
MY
1)
MA
1)
MB
1)
SP
2)
XX
1)
1)
NG25 and NG32 without accu port XX and without ports MA, MB and MY.
2)
NG25 without suction port SP.
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
2/2-Way Active Slip-In Cartridge Valve
Series TDW
8-95
TDW UK.indd 11.07.17
Ordering Code
2/2-way
cartridge
valve DC pilot
Nominal
size
Slip-in
cartridge
Design
Sinus
poppet
Nominal
flow
100 %
Flow
direction
B A
A B
Pilot oil
(supply external,
drain external)
Seal
NBR
1)
Not for start position monitored, Code 8.
2)
Only in combination with start position monitored, code 8).
3)
Only for NG25 to NG63.
4)
Please order female connector M12x1 separately (see accessories directional control valves, female connector M12x1 (order no.: 5004109).
5)
German trade association certificate only legal for pilot options 0 and 2.
6)
Example code 129999: 12 = dia. 1.2 mm, 99 = without orifice.
Solenoid
voltage
DC valve
24 V =
Position
control
Pilot direct
operated
Connector as per
EN175 301-803
Options
DC valve
Code Nominal size
025 NG25
032 NG32
040 NG40
050 NG50
063 NG63
080 NG80
100 NG100
Pilot with DC valve
Code
6)
Nominal size
129999 NG25, NG32
159999 NG40
189999 NG50
209999 NG63
259999 NG80
309999 NG100
Pilot with
cover plate
Code Nominal size
991212 NG25, NG32
991515 NG40
991818 NG50
992020 NG63
992525 NG80
993030 NG100
W 9 C 2 WETDW
Recommended
orifice
P
A
B
N J
Code Pilot
5)
0 w/o DC valve
1
with DC valve,
normally open
2
with cover plate
X = closing
Y = opening
9
with DC valve,
normally closed
Code Poppet shape
1
1)
1:1 standard
8
2)
with overlap
Code Position control
0 w/o position control
2
3)
Stroke limiter
8
4)
Start position
monitored
Code Options
0 Standard
T
without manual
override
Omit for valves
without
DC valve
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
2/2-Way Active Slip-In Cartridge Valve
Series TDW
8-96
TDW UK.indd 11.07.17
General
Design 2-way slip-in cartridge valve according to ISO 7368
Nominal size DIN
NG25 NG32 NG40 NG50 NG63 NG80 NG100
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTF
D
value [years] 75
Weight [kg] 8 10 12 23 49 102 154
Hydraulic
Max. operating pressure [bar] Ports A, B, X up to 350, port Y: max. 210 (350 bar with cover plate)
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -25...+70
Viscosity permitted
recommended
[cSt] / [mm²/s]
[cSt] / [mm²/s]
20...400
30...80
Filtration ISO 4406 (1999); 18/16/13
Nominal flow at p = 5 bar [l/min] 420 850 1500 1900 3600 4500 8000
Recommended max. flow [l/min] 800 2000 3000 4500 8000 13000 20000
Flow direction B to A / A to B
Pilot pressure [bar] must be as high as system pressure
Overlap (for poppet code 8) [mm] 3.7 3.7 3.7 3.7 3.7 3.7 3.7
Electrical characteristics
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP 65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code J
Supply voltage [V] 24 V =
Tolerance supply voltage [%] ±10
Current consumption hold [A] 1.29
Current consumption in rush [A] 1.29
Power consumption hold 31 W
Power consumption in rush 31 W
Solenoid connection
Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code
W).
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
Technical Data / Performance Curves
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
All characteristic curves measured with HLP46 at 50 °C.
p/Q Performance curves (sinus poppet code 1 and 8)
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
2/2-Way Active Slip-In Cartridge Valve
Series TDW
8-97
TDW UK.indd 11.07.17
Position Control
Electrical characteristics of position control M12x1 as per IEC 61076-2-101, NG25 to NG100
M12 pin assignment
1 + U
S
19.2...28.8 V
2 Out B: normally open
3 0V
4 Out A: normally closed
Supply voltage [VDC] 24
Tolernace supply voltage [%] ±20
Ripple supply voltage [%] 10
Polarity protection [V] 300
Current consumption without load [mA] 20
Switching hysteresis [mm] <0.06
Max. output current per channel, ohmic [mA] 250
Ambient temperature [°C] -20 … +60
Protection IP65 acc. EN 60529 (with correctly mounted plug-in connector)
Min. distance to next AC solenoid [m] 0.1
Interface M12x1 to IEC 61076-2-101
CE conform EN 61000-4-2 / EN 61000-4-4 / EN 61000-4-6
1)
/ ENV 50140 / ENV 50204
AC
DC
1
4
2
3
DC
DC st
O
SZ.
U
S
Out
GND
Out neg.
Outputs: Open collector
1)
Only guaranted with screened cable and female connector
2
1
3
4
Please order female connector M12x1 separately (see accessories directional control valves, female connector
M12x1 (order no.: 5004109).
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
2/2-Way Active Slip-In Cartridge Valve
Series TDW
8-98
TDW UK.indd 11.07.17
German trade association certificate
(only valid for pilot options 0 and 2)
Certificate
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
2/2-Way Active Slip-In Cartridge Valve
Series TDW
8-99
TDW UK.indd 11.07.17
Control Surfaces / Dimensions
Control surfaces
A
B
St
A=
100%
A
A
=
B
A
B
A=
A
A
The 1:1 standard poppet (Code 1) is pressure balanced. The overlapped poppet (Code
8) shows smaller areas A
A
respectively A
B
.
E.g. for NG100
A
Nom
= 7854 mm
2
= 600 %
A
St
= 1307 mm
2
= 100 %
A
A
=A
B
= 157 mm
2
= 12 %
Dimensions NG25
NG
Bolt kit
NBR FPM
25 BK504 4x M12x100 ISO 4762-12.9 108 Nm SK-TDW025EN SK-TDW025EV
NG
Pilot oil volume for full
stroke [cm
3
]
A
ST
[%]
Standard poppet 1
A
B
/ A
ST
[%]
Overlapped poppet 8
A
B
/ A
ST
[%]
25 4.7 100 0 10.6
32 5.3 100 0 10.9
40 8.3 100 0 11.2
50 12.9 100 0 11.5
63 18.9 100 0 11.7
80 28.5 100 0 11.8
100 35.3 100 0 12.0
1)
Please order female connector M12x1 separately (see accessories directional control valves, female connector M12x1 (order no.: 5004109).
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
2/2-Way Active Slip-In Cartridge Valve
Series TDW
8-100
TDW UK.indd 11.07.17
Dimensions
NG
Bolt kit
NBR FPM
32 BK529 4 x M16x100 ISO 4762-12.9 264 Nm SK-TDW032EN SK-TDW032EV
40 BK481 4 x M20x110 ISO 4762-12.9 517 Nm SK-TDW040EN SK-TDW040EV
NG32
NG40
1)
Please order female connector M12x1 separately (see accessories directional control valves, female connector M12x1 (order no.: 5004109).
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
2/2-Way Active Slip-In Cartridge Valve
Series TDW
8-101
TDW UK.indd 11.07.17
Dimensions
NG
Bolt kit
NBR FPM
50 BK481 4 x M20x110 ISO 4762-12.9 517 Nm SK-TDW050EN SK-TDW050EV
NG50
1)
Please order female connector M12x1 separately (see accessories directional control valves, female connector M12x1 (order no.: 5004109).
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
2/2-Way Active Slip-In Cartridge Valve
Series TDW
8-102
TDW UK.indd 11.07.17
Dimensions
NG
Bolt kit
NBR FPM
63 BK518 4 x M30x160 ISO 4762-12.9 1775 Nm SK-TDW063EN SK-TDW063EV
NG63
1)
Please order female connector M12x1 separately (see accessories directional control valves, female connector M12x1 (order no.: 5004109).
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
2/2-Way Active Slip-In Cartridge Valve
Series TDW
8-103
TDW UK.indd 11.07.17
Dimensions
NG
Bolt kit
NBR FPM
80 BK530 8x M24x160 ISO 4762-12.9 890 Nm SK-TDW080EN SK-TDW080EV
NG80
1)
Please order female connector M12x1 separately (see accessories directional control valves, female connector M12x1 (order no.: 5004109).
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
2/2-Way Active Slip-In Cartridge Valve
Series TDW
8-104
TDW UK.indd 11.07.17
NG
Bolt kit
NBR FPM
100 BK531 8x M30x150 ISO 4762-12.9 1775 Nm SK-TDW100EN SK-TDW100EV
NG100
Dimensions
1)
Please order female connector M12x1 separately (see accessories directional control valves, female connector M12x1 (order no.: 5004109).
Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
2/2-Way Active Slip-In Cartridge Valve
Series TDW
8-105
TDW UK.indd 11.07.17
t4
d4
d3 min.
d3 max.
d2
15°
t3 and t5
length of fit
1
2
15°
d1
1
2
2
t7
t5
t1
t2
t8
t3
m1
b1
45°
22,5°
35°
Location pin t10 Thread depth t6
d7
d5
d6
XY
d6
m3
m4
d7
d5
m1
m1
m2
Location pin t10 Thread depth t6
XY
b1
b1
m2
Size b1 d1 H7 d2 H7 d3 d3 max d4 max
1)
d5 max d6 d7 H13 m1±0.2 m2±0.2 m3±0.2
25 85 45 34 25 27 32 6 M 12 4 58 33 29
32 102 60 45 32 44 50 8 M 16 6 70 41 35
40 125 75 55 40 54 63 10 M 20 6 85 50 42.5
50 140 90 68 50 67 80 10 M 20 8 100 58 50
63 180 120 90 63 89 100 12 M 30 8 125 75 62.5
80 250 145 110 80 109 110 16 M 24 10 200
100 300 180 135 100 134 150 20 M 30 10 245
Size m4±0.2 t1+0.5 t2+1 t3 t4 t4 max
1)
t5 t6 t7 t8 t10 U W
25 16 58 72 12 44 40.5 30 35 2,5 2,5 10 0.03 0.05
32 17 70 85 13 52 44 15 35 2.5 2.5 10 0.03 0.1
40 23 87 105 15 64 54 15 45 3 3 10 0.05 0.1
50 30 100 122 17 72 59 17 45 4 3 10 0.05 0.1
63 38 130 155 20 95 78 19 65 4 4 10 0.05 0.2
80 175 205 25 130 115 32 50 5 5 10 0.05 0.2
100 210 245 29 155 133 32 53 5 5 10 0.05 0.2
Dimensions
= R
max
16, =
1 2
R
max
8
Required surface finish:
Code: ISO 7368-B*-*-2-A/B NG25 to NG63 Code: ISO 7368-B*-*-2-A NG80 to NG100
1)
Only in combination with d4max and t4max.
Deviating from ISO 7368 it is advisable to
increase the diameters d3, d4 and d5.