Parker Hannifin Corporation
Hydraulics Group
Catalogue HY11-3500/UK
8
2/2-Way Active Slip-In Cartridge Valve
Series TDW
8-96
TDW UK.indd 11.07.17
General
Design 2-way slip-in cartridge valve according to ISO 7368
Nominal size DIN
NG25 NG32 NG40 NG50 NG63 NG80 NG100
Mounting position unrestricted
Ambient temperature [°C] -20...+60
MTTF
D
value [years] 75
Weight [kg] 8 10 12 23 49 102 154
Hydraulic
Max. operating pressure [bar] Ports A, B, X up to 350, port Y: max. 210 (350 bar with cover plate)
Fluid Hydraulic oil according to DIN 51524
Fluid temperature [°C] -25...+70
Viscosity permitted
recommended
[cSt] / [mm²/s]
[cSt] / [mm²/s]
20...400
30...80
Filtration ISO 4406 (1999); 18/16/13
Nominal flow at ∆p = 5 bar [l/min] 420 850 1500 1900 3600 4500 8000
Recommended max. flow [l/min] 800 2000 3000 4500 8000 13000 20000
Flow direction B to A / A to B
Pilot pressure [bar] must be as high as system pressure
Overlap (for poppet code 8) [mm] 3.7 3.7 3.7 3.7 3.7 3.7 3.7
Electrical characteristics
Duty ratio 100 % ED; CAUTION: coil temperature up to 150 °C possible
Protection class IP 65 in accordance with EN 60529 (with correctly mounted plug-in connector)
Code J
Supply voltage [V] 24 V =
Tolerance supply voltage [%] ±10
Current consumption hold [A] 1.29
Current consumption in rush [A] 1.29
Power consumption hold 31 W
Power consumption in rush 31 W
Solenoid connection
Connector as per EN 175301-803, solenoid identification as per ISO 9461 (code
W).
Wiring min. [mm²] 3 x 1.5 recommended
Wiring length max. [m] 50 recommended
Technical Data / Performance Curves
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
All characteristic curves measured with HLP46 at 50 °C.